Spanish Crane Power Line Clearance Requirements Sticker – Tabla A

EC-002SP

This Spanish crane power line clearance requirements sticker combines a printed TABLA A voltage-clearance chart with Spanish electrical-hazard warnings and an illustration of a crane near overhead power lines. Its horizontal red, black and white design has a rectangular PELIGRO header with a triangular alert symbol.

Printed Spanish Warning

PELIGRO
PELIGRO DE ELECTROCUCION
MUERTE O LESION GRAVE

The right panel is headed Despejos Minimos Requeridos Entre Lineas Electricas, as printed on the artwork. Additional text addresses clearance, de-energized and grounded lines, encroachment prevention measures and voltage determination, with references to 1926.1407, .1408 and .1409.

Tabla A Voltage-Clearance Chart

The printed chart is headed TABLA A - Distancias de separación mínimas durante el funcionamiento. It lists nominal voltage ranges and clearance distances in feet and meters. Compare the full chart and wording in the product image with your equipment’s required replacement label.

This description identifies printed label content, not the clearance or procedures required for a particular job. Confirm current applicable requirements and equipment instructions with the qualified person responsible for the work.

Spanish Warning Decal Details

  • Size: 12 inches wide × 5½ inches tall
  • SKU: EC-002SP
  • Spanish-language horizontal layout
  • Crane and overhead-power-line electrocution illustration
  • Laminated decal
  • Created, printed, cut and shipped in the USA

Choosing and Placing Your Replacement Label

Match the language, dimensions, chart, wording and artwork to your equipment manufacturer’s replacement-label requirements. This is a crane warning decal, not a hard-hat label or a determination of approach distances for electrical line workers.

For a cab-operated mobile crane, we recommend a visible panel inside the operator’s cab where the chart can be read from the operating position without obstructing windows or controls. For a ground-control boom truck, we recommend a visible panel beside the crane operating controls where it can be read before operation.

These are general recommendations, not verified factory locations for every model. Use the original label position when known and follow the manufacturer’s decal-location guidance. Do not cover controls, rating plates, instructions or other warnings. Follow the decal’s application instructions and prepare a clean, dry surface.

This sticker communicates a warning. It does not provide electrical protection, prevent accidents or establish regulatory compliance. It does not replace training, job planning, equipment instructions or required hazard controls.

English-Language Alternative

For the English-language counterpart, compare the EC-002 English power line clearance requirements sticker. Both versions measure 12 inches wide × 5½ inches tall. Match the required language and artwork before selecting your replacement.

This sticker measures 12 inches wide × 5½ inches tall. Its SKU is EC-002SP.

Yes. The printed Tabla A chart lists nominal voltage ranges and clearance distances in feet and meters. Compare the full chart and wording with your equipment’s required replacement label.

Yes. EC-002 is the English-language counterpart and measures the same 12 inches wide × 5½ inches tall. A comparison link is included in the description.

For a cab-operated mobile crane, we recommend a visible panel inside the operator’s cab where the chart can be read from the operating position without obstructing windows or controls. For a ground-control boom truck, we recommend a visible panel beside the crane operating controls where it can be read before operation. These are general recommendations, not verified factory locations for every model. Use the original label position when known and follow the manufacturer’s decal-location guidance. Do not cover controls, rating plates, instructions or other warnings.

Technical & Safety Data

Product Composition & Identification

Film Construction: 2.75 mil Polymeric Calendered Vinyl base paired with a 2.75 mil flexible clear Polymeric Calendered Vinyl overlaminate.

Adhesive System: Clear Solvent-Based Permanent Pressure Sensitive Acrylic.

Total Adhesive Thickness: 2.3 mil combined (1.2 mil base and 1.1 mil laminate).

Health, Safety & Regulatory Compliance

Fire Rating: Class A fire rating under ASTM E84-17 testing.

Commercial Safety: Meets the highest life safety requirements for indoor and outdoor commercial graphics.

Toxicity & Structure: Phthalate-Free Film Structure.

Regulatory Standards: Meets the health and safety requirements set forth by CPSIA, REACH, RoHS, and California Proposition 65.

Physical & Chemical Properties

Chemical Resistance: Resists mild acids, mild alkalis, solvents, and salts.

Moisture Resistance: Excellent resistance to water, including full immersion.

Tensile Strength: 12.5 Pounds/Inch.

Dimensional Stability: 0.020 Inch (Machine Direction).

Peel Adhesion: 4.5 Pounds/Inch from Stainless Steel.

Environmental & Temperature Tolerances

Operating Temperature Range: -40°F to 190°F.

Application Temperature: 50°F to 80°F recommended.

Installation Surface: Clean, dry, and free of dust, dirt, debris, or grease.

Outdoor Lifespan: Up to 5 years permanent durability.