This overhead crane hand signal chart shows eight signals for communicating crane movements. Use the plain-language guide below alongside the printed chart, and agree on the applicable signals before a lift.

How to give each hand signal

  • Emergency Stop: Extend both arms horizontally, palms down, and move them back and forth.
  • Stop: Extend one arm horizontally, palm down, and move it back and forth.
  • Bridge Travel: Extend an arm forward with the hand open and slightly raised, then push in the direction the bridge should travel.
  • Lower: Extend an arm downward, point the index finger down, and move the hand in small horizontal circles.
  • Hoist: Hold the forearm vertically, point the index finger up, and move the hand in small horizontal circles.
  • Move Slowly: Give the requested motion signal with one hand while holding the other hand still in front of it.
  • Trolley Travel: Extend an arm with the fingers closed and thumb pointing in the direction of travel, then jerk the hand horizontally.
  • Multiple Trolleys: Hold up fingers to identify the trolley, then give the signal for its movement.

Chart sizes and SKUs

  • 5 × 9 in. — H-002-5x9
  • 6 × 12 in. — H-002
  • 12 × 24 in. — H-002-12x24
  • 18 × 36 in. — H-002-18x36
  • 24 × 48 in. — H-002-24x48

Standards references

For general-industry overhead and gantry cranes, consult OSHA 29 CFR 1910.179 and the ASME standards catalog for B30.2. Construction crane signaling has separate requirements; when applicable, see OSHA 29 CFR 1926.1419 and the hand-signal chart posting rule in 29 CFR 1926.1422. Which requirements apply depends on the crane and work setting. This chart is a visual reference; it does not certify equipment or, by itself, establish compliance.

Need a chart for another crane type? See the mobile crane hand signal chart. For bridge-crane direction labels, see Bridge Crane Stationary Direction Stickers.

Created, printed, cut, and shipped in the USA.

Posting rules depend on the work setting. For construction crane operations covered by OSHA Subpart CC, 29 CFR 1926.1422 requires hand-signal charts to be posted on the equipment or conspicuously near hoisting operations. For general-industry overhead and gantry cranes, follow the requirements that apply to your equipment and workplace.

The chart shows eight signals: Emergency Stop, Stop, Bridge Travel, Lower, Hoist, Move Slowly, Trolley Travel, and Multiple Trolleys. Confirm that the signals used match your crane and work setting.

For Hoist, point your index finger up and move your hand in small horizontal circles. For Lower, point down and circle. Use the chart’s directional gestures for Bridge Travel and Trolley Travel. Move Slowly uses the motion signal with your other hand held still in front; Multiple Trolleys uses raised fingers to identify the trolley.

No. The chart is a visual reference; it does not certify equipment or guarantee compliance. OSHA 29 CFR 1910.179 addresses general-industry overhead and gantry cranes, and ASME B30.2 is the relevant overhead/gantry crane standard family. Construction signal rules in OSHA 29 CFR 1926.1419 and 1926.1422 apply when the work is covered by Subpart CC. Confirm the requirements for your crane and work setting.

5 × 9 in. — H-002-5x9
6 × 12 in. — H-002
12 × 24 in. — H-002-12x24
18 × 36 in. — H-002-18x36
24 × 48 in. — H-002-24x48

This listing is for overhead-crane signals. For mobile-crane signals, use the separate Mobile Crane Hand Signal Chart.

Technical & Safety Data

Product Composition & Identification

Film Construction: 2.75 mil Polymeric Calendered Vinyl base paired with a 2.75 mil flexible clear Polymeric Calendered Vinyl overlaminate.

Adhesive System: Clear Solvent-Based Permanent Pressure Sensitive Acrylic.

Total Adhesive Thickness: 2.3 mil combined (1.2 mil base and 1.1 mil laminate).

Health, Safety & Regulatory Compliance

Fire Rating: Class A fire rating under ASTM E84-17 testing.

Commercial Safety: Meets the highest life safety requirements for indoor and outdoor commercial graphics.

Toxicity & Structure: Phthalate-Free Film Structure.

Regulatory Standards: Meets the health and safety requirements set forth by CPSIA, REACH, RoHS, and California Proposition 65.

Physical & Chemical Properties

Chemical Resistance: Resists mild acids, mild alkalis, solvents, and salts.

Moisture Resistance: Excellent resistance to water, including full immersion.

Tensile Strength: 12.5 Pounds/Inch.

Dimensional Stability: 0.020 Inch (Machine Direction).

Peel Adhesion: 4.5 Pounds/Inch from Stainless Steel.

Environmental & Temperature Tolerances

Operating Temperature Range: -40°F to 190°F.

Application Temperature: 50°F to 80°F recommended.

Installation Surface: Clean, dry, and free of dust, dirt, debris, or grease.

Outdoor Lifespan: Up to 5 years permanent durability.