Crawler Crane Is Not Insulated Electrocution Hazard Sticker

EC-001CrLa

This crawler and lattice boom crane electrocution hazard sticker displays THIS CRANE IS NOT INSULATED wording with an illustration of a tracked crawler crane near overhead electrical lines. Its horizontal red, black and white layout combines a rectangular DANGER header and triangular alert symbol with printed operator and ground-personnel warnings.

Printed Warning Text

DANGER
ELECTROCUTION HAZARD
THIS CRANE IS NOT INSULATED

To avoid death or serious injury keep all parts of this crane, the rigging and materials being lifted at least 20 feet away from all electrical power lines and equipment.

Keep away from this crane if it is being operated near electrical power lines or equipment.

Before operating this crane in the vicinity of power line or equipment notify the power utility company. Have power turned off.

Follow instructions in operator's manual and safety handbook.

The illustration panel repeats THIS CRANE IS NOT INSULATED. The quoted warning describes the artwork, not the clearance or procedures required for a particular job. Do not treat the printed 20-foot statement as a universal clearance determination. Confirm current applicable requirements and equipment instructions with the qualified person responsible for the work.

Crawler Crane Warning Decal Details

  • Size: 10½ inches wide × 5½ inches tall
  • SKU: EC-001CrLa
  • English-language horizontal design
  • Tracked crawler crane and lattice-boom electrocution illustration
  • Vinyl decal with UV laminate
  • Text-warning design without a voltage-clearance chart
  • Created, printed, cut and shipped in the USA

Choosing Your Replacement Label

Match the dimensions, printed warning and illustration to your equipment manufacturer's replacement-label requirements. This is a warning decal for non-insulated crane equipment, not an insulated-boom product or a source of electrical protection. The crawler illustration does not establish compatibility with every crawler or lattice boom crane.

Recommended Placement

For a cab-operated crawler or lattice boom crane, we recommend a visible interior cab panel near the operating controls where the operator can read the warning from the seated operating position. Do not obstruct windows, controls, instruments, load charts or other warnings.

If replacing an exterior warning intended for ground personnel, use the manufacturer's specified exterior location where those personnel can see it. An interior cab label alone may not communicate the warning to people outside the cab.

These are general recommendations, not verified factory locations for every model. Use the original label position when known and follow the manufacturer's decal-location diagram. Follow the decal's application instructions and prepare a clean, dry surface.

This sticker communicates a warning. It does not provide electrical protection, prevent accidents, reduce legal liability or establish ASME compliance. It does not replace training, job planning, manufacturer instructions or required hazard controls.

Compare Electrical Hazard Designs

For a crawler/lattice-boom design with a printed Table A voltage-clearance chart, compare the EC-002CrLa crawler crane power line clearance sticker. For the different EC-001 artwork and voltage-chart layout, compare the EC-001 crane electrical hazard sticker. Match the required wording and artwork; these designs are not automatically interchangeable replacements.

This sticker measures 10½ inches wide × 5½ inches tall. Its SKU is EC-001CrLa.

No. EC-001CrLa combines printed electrical-hazard warnings with a crawler/lattice-boom crane illustration. For a crawler design with a Table A chart, compare EC-002CrLa using the link in the description.

The label displays “DANGER,” “ELECTROCUTION HAZARD” and “THIS CRANE IS NOT INSULATED.” Additional printed text addresses keeping crane parts, rigging and lifted materials away from electrical lines, warning ground personnel, notifying the power utility and following the operator’s manual and safety handbook.

For a cab-operated crawler or lattice boom crane, we recommend a visible interior cab panel near the operating controls where the warning can be read from the seated operating position. If replacing an exterior warning intended for ground personnel, use the manufacturer’s specified exterior location where those personnel can see it. These are general recommendations, not verified factory locations for every model. Use the original label position when known and follow the manufacturer’s decal-location diagram. Do not obstruct windows, controls, instruments, load charts or other warnings.

Technical & Safety Data

Product Composition & Identification

Film Construction: 2.75 mil Polymeric Calendered Vinyl base paired with a 2.75 mil flexible clear Polymeric Calendered Vinyl overlaminate.

Adhesive System: Clear Solvent-Based Permanent Pressure Sensitive Acrylic.

Total Adhesive Thickness: 2.3 mil combined (1.2 mil base and 1.1 mil laminate).

Health, Safety & Regulatory Compliance

Fire Rating: Class A fire rating under ASTM E84-17 testing.

Commercial Safety: Meets the highest life safety requirements for indoor and outdoor commercial graphics.

Toxicity & Structure: Phthalate-Free Film Structure.

Regulatory Standards: Meets the health and safety requirements set forth by CPSIA, REACH, RoHS, and California Proposition 65.

Physical & Chemical Properties

Chemical Resistance: Resists mild acids, mild alkalis, solvents, and salts.

Moisture Resistance: Excellent resistance to water, including full immersion.

Tensile Strength: 12.5 Pounds/Inch.

Dimensional Stability: 0.020 Inch (Machine Direction).

Peel Adhesion: 4.5 Pounds/Inch from Stainless Steel.

Environmental & Temperature Tolerances

Operating Temperature Range: -40°F to 190°F.

Application Temperature: 50°F to 80°F recommended.

Installation Surface: Clean, dry, and free of dust, dirt, debris, or grease.

Outdoor Lifespan: Up to 5 years permanent durability.