Crawler & Lattice Boom Crane Power Line Clearance Sticker

EC-002CrLa

This crawler and lattice boom crane power line clearance sticker combines a printed Table A voltage-clearance chart with an illustration of a tracked crawler crane and lattice boom near overhead electrical lines. The red DANGER header includes a triangular alert symbol above POWER LINE CLEARANCE REQUIREMENTS.

Printed Electrical Hazard Warning

DANGER
POWER LINE CLEARANCE REQUIREMENTS
ELECTROCUTION HAZARD
DEATH OR SERIOUS INJURY

The right panel includes printed text addressing clearance, de-energized and grounded lines, encroachment prevention measures and voltage determination. The text references 1926.1407, .1408 and .1409.

Table A Voltage-Clearance Chart

The chart is headed TABLE A – Minimum Clearance Distances While in Operation. It lists nominal alternating-current voltage ranges and clearance distances in feet and meters. Compare the complete chart and wording in the product image with your equipment’s required replacement label.

This description identifies printed label content, not the clearance or procedures required for a particular job. Confirm current applicable requirements and equipment instructions with the qualified person responsible for the work.

Crawler Crane Warning Decal Details

  • Size: 12 inches wide × 5½ inches tall
  • SKU: EC-002CrLa
  • English-language horizontal label
  • Red, black and white design with a crawler/lattice-boom crane electrocution illustration
  • Created, printed, cut and shipped in the USA

Choosing and Placing Your Replacement Label

Match the wording, chart, dimensions and illustration to your crane manufacturer’s replacement-label requirements. The crawler crane illustration distinguishes this design from the telescopic-boom EC-002 artwork; it does not establish compatibility with every crawler crane.

For a cab-operated crawler or lattice boom crane, we recommend a visible interior cab panel near the operating controls where the operator can read the chart from the seated operating position. Do not obstruct windows, controls, instruments, load charts or other warnings.

This is general placement guidance, not a verified factory location for every model. Use the original label position when known and follow the manufacturer’s decal-location diagram. An exterior location alone may not make the chart readable to the seated operator. Follow the decal’s application instructions and prepare a clean, dry surface.

This sticker communicates a warning. It does not provide electrical protection, prevent accidents, generate audible alerts or establish regulatory compliance. It does not replace job planning, training, manufacturer instructions or required hazard controls.

Compare Other Power Line Warning Designs

For the telescopic-boom illustration, compare the EC-002 crane power line clearance sticker. For the separately customized chart requested by a Canadian customer, compare the EC-002CrLa-CA custom crawler crane clearance sticker. The custom designation does not establish suitability throughout Canada. Match the required chart and wording; these designs are not automatically interchangeable.

Need a different size? Contact us about custom sizes.

This sticker measures 12 inches wide × 5½ inches tall. Its SKU is EC-002CrLa.

This version depicts a tracked crawler crane with a lattice boom. Standard EC-002 uses a telescopic-boom crane illustration. Compare the complete wording, chart and artwork with your equipment’s required replacement label.

Yes. The printed chart is headed “TABLE A – Minimum Clearance Distances While in Operation” and lists nominal voltage ranges with clearance distances in feet and meters.

For a cab-operated crawler or lattice boom crane, we recommend a visible interior cab panel near the operating controls where the operator can read the chart from the seated operating position. Do not obstruct windows, controls, instruments, load charts or other warnings. This is general guidance, not a verified factory location for every model. Use the original label position when known and follow the manufacturer’s decal-location diagram.

Technical & Safety Data

Product Composition & Identification

Film Construction: 2.75 mil Polymeric Calendered Vinyl base paired with a 2.75 mil flexible clear Polymeric Calendered Vinyl overlaminate.

Adhesive System: Clear Solvent-Based Permanent Pressure Sensitive Acrylic.

Total Adhesive Thickness: 2.3 mil combined (1.2 mil base and 1.1 mil laminate).

Health, Safety & Regulatory Compliance

Fire Rating: Class A fire rating under ASTM E84-17 testing.

Commercial Safety: Meets the highest life safety requirements for indoor and outdoor commercial graphics.

Toxicity & Structure: Phthalate-Free Film Structure.

Regulatory Standards: Meets the health and safety requirements set forth by CPSIA, REACH, RoHS, and California Proposition 65.

Physical & Chemical Properties

Chemical Resistance: Resists mild acids, mild alkalis, solvents, and salts.

Moisture Resistance: Excellent resistance to water, including full immersion.

Tensile Strength: 12.5 Pounds/Inch.

Dimensional Stability: 0.020 Inch (Machine Direction).

Peel Adhesion: 4.5 Pounds/Inch from Stainless Steel.

Environmental & Temperature Tolerances

Operating Temperature Range: -40°F to 190°F.

Application Temperature: 50°F to 80°F recommended.

Installation Surface: Clean, dry, and free of dust, dirt, debris, or grease.

Outdoor Lifespan: Up to 5 years permanent durability.