Crane Power Line Clearance Chart Sticker – Not Insulated Warning

EC-003

This crane power line clearance chart sticker combines a printed Table A chart with POWER LINE CLEARANCE REQUIREMENTS and THIS CRANE IS NOT INSULATED warnings. The horizontal layout features a rectangular red DANGER header with a triangular alert symbol and a power-line illustration with a red arrow.

Printed Electrical Hazard Warning

DANGER
POWER LINE CLEARANCE REQUIREMENTS
ELECTROCUTION HAZARD
THIS CRANE IS NOT INSULATED

The printed text addresses overhead power line clearance, de-energized and grounded lines, encroachment prevention measures and voltage determination. It references 1926.1407, .1408 and .1409.

Table A Voltage-Clearance Chart

The chart is headed TABLE A – Minimum Clearance Distances While in Operation. It lists nominal alternating-current voltage ranges and clearance distances in feet and meters. Review the product image to compare the complete chart and warning text with your equipment’s required replacement label.

This description identifies printed label content, not the clearance or procedures required for a particular job. Confirm current applicable requirements and your equipment manufacturer’s instructions with the qualified person responsible for the work.

Replacement Decal Details

  • Size: 10 inches wide × 5½ inches tall
  • SKU: EC-003
  • English-language horizontal warning label
  • Red, black and white design with a power-line illustration
  • Laminated decal
  • Created, printed, cut and shipped in the USA

Choosing and Placing the Warning Label

Match the wording, dimensions, voltage chart and artwork to your equipment manufacturer’s replacement-label requirements. This crane warning decal is not a hard-hat label or a determination of approach distances for electrical line workers.

For a cab-operated mobile crane, we recommend a visible panel inside the operator’s cab where the chart can be read from the operating position without obstructing windows or controls. For a ground-control boom truck, we recommend a visible panel beside the crane operating controls where it can be read before operation.

These are general recommendations, not verified factory locations for every model. Use the original warning-label position when known and follow the manufacturer’s decal-location guidance. Do not cover controls, rating plates, instructions or other warnings. Follow the decal’s application instructions and prepare a clean, dry surface.

This sticker communicates a warning. It does not insulate equipment, provide electrical protection, prevent accidents or establish regulatory compliance. It does not replace training, job planning, manufacturer instructions or required hazard controls.

Spanish-Language Alternative

For the Spanish-language counterpart, compare the EC-003SP Spanish crane power line clearance chart sticker. Match the required language, dimensions and artwork before ordering.

Compare Other Electrical Warning Designs

Compare the EC-002 power line clearance requirements decal for a different illustration and a 12 × 5½-inch layout, or the EC-001 crane electrical hazard sticker for a different warning and voltage-chart layout. These designs are not automatically interchangeable replacements.

This sticker measures 10 inches wide × 5½ inches tall. Its SKU is EC-003.

Yes. The printed chart is headed “TABLE A – Minimum Clearance Distances While in Operation” and lists nominal voltage ranges with clearance distances in feet and meters. Compare the full artwork with your equipment’s required replacement label.

Yes. EC-003SP is the Spanish-language counterpart. A comparison link is included in the description so you can check its language, dimensions and artwork before ordering.

For a cab-operated mobile crane, we recommend a visible panel inside the operator’s cab where the chart can be read from the operating position without obstructing windows or controls. For a ground-control boom truck, we recommend a visible panel beside the crane operating controls where it can be read before operation. These are general recommendations, not verified factory locations for every model. Use the original label position when known and follow the manufacturer’s decal-location guidance. Do not cover controls, rating plates, instructions or other warnings.

Technical & Safety Data

Product Composition & Identification

Film Construction: 2.75 mil Polymeric Calendered Vinyl base paired with a 2.75 mil flexible clear Polymeric Calendered Vinyl overlaminate.

Adhesive System: Clear Solvent-Based Permanent Pressure Sensitive Acrylic.

Total Adhesive Thickness: 2.3 mil combined (1.2 mil base and 1.1 mil laminate).

Health, Safety & Regulatory Compliance

Fire Rating: Class A fire rating under ASTM E84-17 testing.

Commercial Safety: Meets the highest life safety requirements for indoor and outdoor commercial graphics.

Toxicity & Structure: Phthalate-Free Film Structure.

Regulatory Standards: Meets the health and safety requirements set forth by CPSIA, REACH, RoHS, and California Proposition 65.

Physical & Chemical Properties

Chemical Resistance: Resists mild acids, mild alkalis, solvents, and salts.

Moisture Resistance: Excellent resistance to water, including full immersion.

Tensile Strength: 12.5 Pounds/Inch.

Dimensional Stability: 0.020 Inch (Machine Direction).

Peel Adhesion: 4.5 Pounds/Inch from Stainless Steel.

Environmental & Temperature Tolerances

Operating Temperature Range: -40°F to 190°F.

Application Temperature: 50°F to 80°F recommended.

Installation Surface: Clean, dry, and free of dust, dirt, debris, or grease.

Outdoor Lifespan: Up to 5 years permanent durability.